Hot Stamping Machine Control
Main Screen
Time settings:
1.PRINT TIME. Sets the time the head is down on the part being printed.
2.FOIL BACKUP DELAY TIME.
3.FOIL BACKUP TIME.
4.HEAD UP DELAY TIME. Sets the time from when the head starts up until it stops going up.
5.HEAD UP STOP TIME. Sets the time the head stops before moving up to the up position.
6.FOIL PULL DELAY TIME. Sets the time from when the head starts up until the foil starts to pull.
7.FOIL PULL TIME. Sets the time the foil is being pulled.
Buttons:
1.FOIL FEED. Pulls the foil for as long as it is touched.
2.PULL SELECT. Selects the foil pull function, BEFORE, AFTER, or OFF
3.DEBUG SCREEN. Change to the DEBUG screen.
4.MAIN SCREEN. Change to the MAIN screen.
4.CNT RESET. Resets the machine cycle counter.
Indicators:
1.TEMP ALARM. Indicates if the temperature is within the alarm range. If RED, the machine will not run.
2.COUNTER. Indicates the number of machine cycles since the last counter reset.
Control Boc PLC no Disconnect
SERVING THE PLASTICS INDUSTRY SINCE 1979 WITH SYSTEMS